三、减速器的承载能力及选用方法
1. CCWU. CCWO及CCWS减速器的额定输入功率P1及输出转短T2应符合表7的规定。
Rated imput power P1 and output torque T2 of CCWU,CCWO,and CCWs reducers Confor to stipulation of table 7
2. GCWU. GCWO及GCWS减速器的额定输入功率P1及输出转短T2应符合表8的规定。
Rated imput power P1 and output torque T2 of GCWU,GCWO,and GCWS reducers Conform to stipulation of table 8
3.减速器输出轴轴端的许用负荷及确定方法应符合GB9147-88附录C中C4的规定。
Allowed load of output shaft conforms to stipulation of GB9147-88 appedixC-C4
4.减速器的效率应分别依据表7.8中的P1及T2由下式计算。Eficiency is calculated by the formula below according to P1.T2 in table7.8
式中为减速器的实际速比。of which P-atual speed rate.
5.表7.表8中的额定输入功率P1及额定输出转矩T2适用于如下工作条件:减速器工作负荷平稳无冲击.每日工作8小时,每小时启动10次,小时负荷率Jc= ****,环境温度20C.极限油温100'C。 当上述条件不满足时,应依据表9-表12进行修正。
5.The working situation is as fllows, stable working load,8 hours/day, starup 10 times/hour, load eficieney JC= **** per hour,ambient temperature 20'C ,max oil temperature 100'C
5.1载荷系数f1见表9。5.1load factor f1 is show in table 9